Understanding Airflow Engineering in Dust Collection Systems

Expert Insight on Mining Dust Collection

A dust collector can be running exactly as designed and still allow dust to escape into your operations. That’s because effective dust collection depends on more than the collector itself. Airflow must be properly engineered and balanced throughout the entire system to capture fugitive dust where it’s created.

Changes in production, material, equipment or pickup points can disrupt that balance over time. Too little airflow can allow dust to escape and accumulate throughout a facility, while too much can pull valuable product out of the process. Poor airflow can also lead to duct buildup, increased maintenance, equipment wear and higher energy costs. The result is a system that may appear operational without delivering the dust containment performance your facility needs.

In this Q&A Mike Evins, Application Engineer at C&W DustTech, explains how operators can recognize airflow problems, what causes systems to become unbalanced and how a system-level engineering approach can ensure dust is controlled.

Do airflow engineering requirements differ across industries like Aggregates, Mining and Cement?

Yes and no. The basic principles are similar across all dry dust collection equipment. Certain engineering considerations change depending on each application. Some considerations are based on industry. For example, operators might need abrasion prevention in Mining and Aggregates or moisture control in Cement. While these are common broader considerations to look at, you really need to examine how you can collect fugitive dust at creation points to be successful. That’s based on each individual system, not necessarily by industry.

What are the hidden costs or poor airflow engineering?

When airflow isn’t properly engineered across the entire dust collection system, the consequences impact people, maintenance, productivity and product value. Those consequences can include:

  • Long-term health risks for workers exposed to airborne particulate.
  • Continual buildup in ducting leading to resource inefficiency and increased maintenance.
  • Product material loss from fugitive dust.
  • Reduced product value when overcollection captures usable material that must be repurposed or sold at a lower value.

Can airflow problems reduce production efficiency?

Yes, the quality of your product can be the main problem, but hidden costs include additional wear on dirty bearings or belts in your production equipment.

What are some of the common “symptoms” operators might be experiencing if they have an airflow balancing issue?

Common issues might include continual maintenance on dust collectors, which can lead to material buildup in the ducting and blocked airflow, or someone changing the system down the road by adding or removing pickup points. Sometimes, it’s changes in the material or product in the process. The main question operators should always ask is: “What’s changed?”.

How do operators know how much airflow they actually need?

We have calculations developed by The American Conference of Governmental Industrial Hygienists (ACGIH) and The National Institute for Occupational Safety and Health (NIOSH) that explain how much airflow to apply at collection points. These are all based on the types of hoods, amount of enclosure and the velocity or motion of the product. For operators, visible escaping dust or buildup can signal insufficient airflow, while too much airflow can pull valuable product from the process. So, it’s a balancing act.

We offer comprehensive engineering audits to help operators analyze and balance their airflow.

How do operators address unbalanced pickup points?

First, check for collector performance or maintenance issues that could cause duct buildup or blockages. An engineering audit is the best way to uncover any issues with your collector. Audits provide a more comprehensive view of system performance by evaluating actual operating conditions, airflow, ductwork and pickup points to identify where imbalances are occurring and why. This helps operators move beyond individual adjustments and address the root cause of poor dust capture, ensuring changes improve containment across the entire system rather than simply shifting the problem from one pickup point to another. If an audit finds that your system is clear, adjusting blast gates can help rebalance airflow across pickup points.

Should airflow be adjusted seasonally?

Not necessarily seasonally, but it should be adjusted to accommodate fluctuations in process or even the conditions of your dust collector over time. One simple way to do this is to add a variable speed drive to maintain the desired airflow by speeding up the fan as the filters get dirtier or slowing the fan down after the filters clean or get replaced.

How can you increase air throughout with existing collectors/technologies?

Ducting is designed for a specific amount of airflow at a specific pressure. We can push that to the limit, but doing so may introduce higher energy bills (more horsepower) or start generating abrasion in the system. Most of the time, it’s beneficial to have a dust collection partner who can evaluate our process and determine the right path forward.

How do transfer points impact airflow? Are there separate considerations based on process?

Transfer points are critical to airflow engineering because they are often where the greatest dust-control demands occur. As material drops, changes direction or moves from one conveyor or process step to another, it displaces air and generates airborne dust. Effective airflow engineering must account for those conditions. However, transfer points can’t always be designed to reduce dust generation. Reducing the fall height, slowing conveyors down and fully enclosing the area are the best ways to help reduce dust build-up, but this is challenging in most situations. We can help by collecting the dust that’s generated and putting it back on the belt to continue on in the process. The primary goal here is to capture fugitive dust from the process that can be breathed by workers or lost to the environment.

Mike Evins, Application Engineer

Joining C&W in 2017, Mike has become our resident expert on dust collection system design. His deep experience and customer focus help us to customize high-performing solutions and educate our stakeholders on effective dust collection.

His knowledge is critical as he works alongside the Production Engineering team to engineer dust collectors and systems for demanding applications. He also works closely with our Sales and Customer Success teams to meet the rigorous requirements of our partners and end users. Mike serves a critical role as educator, helping his peers, customers and partners understand their dust and specifics of clean air technologies.